  Datasheet File OCR Text:
  ? no more writing data down. capture up to 65000 sets of min/max/avg readings over single or multiple logging sessions using the recording capability. each reading and session is time stamped ? avoid awkward or uncomfortable measurement positions. set up the measurement once, step back and read it as many times as you want, when you want ? identify up to 10 placed modules with meter or pc and choose only the ones you need ? view up to 10 live readings at once on a pc to get a complete understanding of the situation ? easily see backlit displays in dark or dimly lit work environments ? choose auto or manual ranging ? use the optional tpak magnetic hanger for even more hands-free working ? integrated holster protects the meters, while probe holders keep accessories organized safety ? increase safety by taking readings in a separate location than the point of measurement ? fluke cnx meets measurement category 1000 v cat iii and category iv 600 v safety standards: ac current clamp 600 v cat iii; ac voltage module and iflex clamp meters 600 v cat iv / 1000 cat iii fluke cn x 3000 series test tools the fluke wireless team the new fluke wireless troubleshooting team lets you see live measurements from multiple modules simultaneously and remotely on a single screen. this customizable tool set, built with the durability, reliability and quality youve come to expect from fluke tools, will change the way you work. wireless multimeter displays readings from up to three wireless modules, plus the meter from up to 20 meters away. add a laptop and review ten measurements at once. fluke cnx 3000 series ? digital multimeter ? ac voltage module ? ac true-rms current clamp module ? iflex true-rms ac current clamp module ? k-type temperature module ? pc adapter productivity ? save money and time by taking multiple measure- ments simultaneously ? isolate intermittent events or record signal fluc- tuations without even being there using the log function on the modules ? work with fewer interruptions by recording multiple sessions before downloading. data is saved to a pc in .csv format (comma separated variable) file format for easy viewing at your convenience ? capture readings at different intervals, with user-set recording intervals from one second to one hour ? choose the module(s) that work best for your applications convenience ? no more run-around. see up to four measurements (dmm and 3 modules) on one screen, in one place at the same time. technical data ?
2 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. fluke cnx 3000 series wireless multimeter detailed specifications for all specifications: accuracy is specified for one year after calibration, at operating tem- peratures of 18 c to 28 c, with relative humidity at 0 % to 90 %. accuracy specifications take the form of ([ % of reading ] + [ number of least significant digits ]). ac voltage range 1 resolution accuracy 2,3 45?hz to 500?hz 500?hz to 1?khz 600.0?mv 0.1?mv 1.0?% + 3 2.0?% + 3 6.000?v 0.001?v 60.00?v 0.01?v 600.0?v 0.1?v 1000?v 1?v 1 all ac voltage ranges are specified from 1?% of range to 100?% of range. 2 crest factor of 3 at full scale up to 500?v, decreasing linearly to crest factor < 1.5 at 1000?v. 3 for non-sinusoidial waveforms, add C(2?% of reading + 2?% full scale) typical, for crest factor up to 3. dc voltage, continuity, resistance, diode test and capacitance function range resolution accuracy mv 600.0?mv 0.1?mv 0.09?% + 2 v 6.000?v 0.001?v 0.09?% + 2 60.00?v 0.01?v 600.0?v 0.1?v 1000?v 1?v 0.15?% + 2 ? 600? 1? meter beeps at < 25?, beeper detects opens or shorts of 250?s or longer. ? 600.0? 0.1? 0.5?% + 2 6.000?k 0.001?k 0.5?% + 1 60.00?k 0.01?k 60.00?k 0.1?k 600.0?k 0.001?m 50.00?m 0.01?m 1.5?% + 3 diode test 2.000?v 0.001?v 1?% + 2 f 1000?nf 1?nf 1.2?% + 2 10.00?f 0.01?f 100.0?f 0.1?f 9999?f 1 1?f 10?% typical 1 in the 9999?f range for measurements to 1000?f, the measurement accuracy is 1.2?% + 2. ac and dc current function range 1 resolution accuracy ma ac (45?hz to 1?khz) 60.00?ma 0.01?ma 1.5?% + 3 400.0?ma 3 0.1?ma ma dc 2 60.00?ma 0.01?ma 0.5?% + 3 400.0?ma 0.1?ma 1 all ac current ranges are specified from 5?% of range to 100?% of range. 2 input burden voltage (typical): 400?ma input 2?mv/ma. 3 400.0 ma accuracy specified up to 600?ma overload. specifications contents
3 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. frequency range resolution accuracy [1] 99.99?hz 0.01?hz 0.1?% + 1 999.9?hz 0.1?hz 9.999?khz 0.001?khz 99.99?khz 0.01?khz 1 frequency is specified up to 99.99?khz in volts and up to 10?khz in amps. input characteristics function overload protection input impedance (nominal) common mode rejection ratio (1 k unbalance) normal mode rejection 1100 v rms > 10 m < 100 pf > 120 db at dc, 50 hz or 60 hz > 60 db at 50 hz or 60 hz 1100 v rms > 10 m < 100 pf > 60 db, dc to 60 hz 1100 v rms > 10 m < 100 pf > 120 db at dc, 50 hz or 60 hz > 60 db at 50 hz or 60 hz open circuit test voltage full scale voltage typical short circuit current to 6 m 50 m 1100 v rms < 2.7 v dc < 0.7 v dc < 0.9 v dc < 350 ma 1100 v rms < 2.7 v dc 2.000 v dc < 1.1 ma function overload protection overload ma fused, 44/100?a, 1000?v fast fuse 600?ma overload for 2?minutes maximum, 10?minutes rest minimum min/max recording function accuracy dc functions the specified accuracy of the measurement function 12 counts for changes > 350 ms in duration. ac functions the specified accuracy of the measurement function 40 counts for changes > 900 ms in duration. general specifications maximum voltage between any terminal and earth ground 1000 v dc or ac rms fuse protection from a inputs 0.44 a (44/100 a, 440 ma), 1000 v fast fuse, fluke specified part only display (lcd) update rate: 4/sec votls, amps, ohms: 6000 counts frequency: 10,000 counts capacitance: 1,000 counts battery type three aa alkaline batteries, neda 15a iec lr6 battery life 300 hours minimum rf communications 2.4 ghz ism band rf communication range 20?meters temperature operating: -10 c to 50 c storage: -40 c to 60 c temperature coeffcient 0.1 x (specified accuracy) /c (<18 c or >28 c) relative humidity 0 % to 90 % (0 c to 35 c), 0 % to 75 % (35?c to 40?c), 0?% to 45?% (40?c to 50?c) altitude operating: 2,000 m storage: 12,000 m electromagnetic compatibilty emi, rfi, emc, rf en 61326-1:2006, en 61326-2-2:2006. etsi en 300 328 v1.7.1:2006, etsi en 300 489 v1.8.1:2008, fcc part 15 subpart c sections 15.207, 15.209, 15.249, fccid : t68-fwcs ic:6627a-fwcs safety compliance us ansi: ansi/isa 61010-1 / (82.02.01): 3 rd edition csa: can/csa-c22.2 no 61010-1-12: 3 rd edition ce european: iec/en 61010-1:2010 certifications csa, fcc, ce ingress protection (ip) rating ip54 size (h x w x l) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) weight 340 g (12 oz)
4 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. fluke cnx 3000 series ac voltage module accuracy is specified as ([% of reading] + [number of least significant digits]). all ranges are autoranging. accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 c to 28 c. ac voltage range 1 resolution accuracy 2,3 45?hz to 500?hz 500?hz to 1?khz 6.000?v 0.001?v 1.0?% + 3 2.0?% + 3 60.00?v 0.01?v 600.0?v 0.1?v 1000?v 1?v 1 all ac voltage ranges are specified from 1?% of range to 100?% of range. 2 crest factor of 3 at full scale up to 500?v, decreasing linearly to crest factor 1.5 at 1000?v. 3 for non-sinusoidial waveforms, add C(2?% of reading + 2?% full scale) typical, for crest factor up to 3. general specifications lcd w/backlight 3? digits, 6000 counts, updates 4/sec battery type 2 aa, neda 15?a, iec lr6 battery life 400 hours memory record up to 65000 readings rf communications 2.4 ghz ism band rf communication range 20?meters operating temperature -10?c to +50?c storage temperature -40?c to +60?c temperature coefficient 0.1?x (specified accuracy)/c (< 18?c or > 28?c) operating humidity 90?% at 35?c, 45?% at 40?c, 45?% at 50?c emc en 61326-1:2006 safety compliance en/iec 61010-1:2010 to 1000 v measurement category (cat) iii 600 v measurement category (cat) iv en/iec 61010-2-030:2010 en/iec 61010-031:2002+a1:2008 safety rating cat iv 600 v, cat iii 1000 v certifications csa, fcc t68-fwcs ic:6627a-fwcs ingress protection (ip) rating ip42 size (hxwxd) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) weight .22 kg (8 oz) contents
5 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. fluke cnx 3000 series true-rms ac current clamp module general specifications range 0.5 a to 400.0 a resolution 0.1?a accuracy 400.0 a: 2?% 5 digits (10?hz to 100?hz), 2.5?% 5 digits (100?hz to 500?hz) inrush max displayed reading: 999.9a crest factor (50?hz/60?hz) 3 at 500?a, 2.5 at 600?a, 1.42 at 1000?a, add 2?% for c.f. > 2 lcd w/backlight 3? digits log rate/interval 1 sec minimum/adjustable by pc battery type 2 aa, neda 15?a, iec lr6 battery life 400 hours memory record up to 65,000 readings rf communications 2.4 ghz ism band rf communication range 20?meters operating temperature -10?c to +50?c storage temperature -40?c to +60?c temperature coefficient add 0.1?x (specified accuracy)/c (< 18?c or > 28?c) operating humidity 90?% at 35?c, 75?% at 40?c, 45?% at 50?c emc en 61326-1:2006 safety compliance en/iec 61010-1-030:2010 to 600 v measurement category (cat) iii en/iec 61010-2-030:2010 en/iec 61010-032:2002 safety rating cat iii 600 v certifications csa, fcc t68-fwcs ic:6627a-fwcs ingress protection (ip) rating ip30 jaw opening 34 mm (1.33 in) size (hxwxd) 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in) weight .22 kg (8 oz)
6 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. fluke cnx 3000 series iflex true-rms ac current clamp module general specifications range 0.5 a to 2500 a ac resolution 0.1 a accuracy 3?% 5 digits crest factor (50?hz/60?hz) 3.0 at 1100?a, 2.5 at 1400?a, 1.42 at 2500?a, add 2?% for c.f. > 2 lcd w/backlight 3? digits log rate/interval 1 sec minimum/adjustable by pc or front panel battery type 2 aa, neda 15?a, iec lr6 battery life 400 hours memory record up to 65,000 readings rf communications 2.4 ghz ism band rf communication range 20?meters operating temperature -10?c to +50?c storage temperature -40?c to +60?c temperature coefficient add 0.1?x (specified accuracy)/ c (<18?c or >28?c) operating humidity 90?% at 35?c, 75?% at 40?c, 45?% at 50?c emc en 61326-1:2006 safety compliance en/iec 61010-1:2010 to 1000 v measurement category (cat) iii 600 v measurement category (cat) iv en/iec 61010-2-030:2010 en/iec 610101-2-031:2002 en/iec 61010-2-032:2002 safety rating cat iv 600 v, cat iii 1000 v certifications csa, fcc t68-fwcs ic:6627a-fwcs ingress protection (ip) rating ip42 jaw opening 25.4 cm (10 in) coil size (hxwxd) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) weight .22 kg (8 oz)
7 fluke corporation fluke cnx 3000 series test tools. the fluke wireless team. fluke cnx 3000 series k-type temperature module general specifications range k-type: -200?c to 1372?c resolution 0.1?c accuracy [0.5?% + 0.3?c] counts input terminals k-type mini lcd w/backlight 3 ? digits log rate/interval 1 sec minimum/adjustable by pc battery type 2 aa, neda 15?a, iec lr6 battery life 400 hours memory record up to 65,000 readings rf communications 2.4 ghz ism band rf communication range 20?meters operating temperature -10?c to +50?c storage temperature -40?c to +60?c temperature coefficient 0.01?% of reading +0.03?c per c temperature scale its-90 operating humidity 90?% at 35?c, 75?% at 40?c, 45?% at 50?c emc en 61326-1:2006 safety compliance cat i per iec/en 61010-1:2010, en/iec 61010-2-030:2010 certifications csa, fcc t68-fwcs ic:6627a-fwcs ingress protection (ip) rating ip30 size (hxwxd) 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) weight .22 kg (8 oz) fluke corporation po box 9090, everett, wa 98206 u.s.a. fluke europe b.v. po box 1186, 5602 bd eindhoven, the netherlands for more information call: in the u.s.a. (800) 443-5853 or fax (425) 446-5116 in europe/m-east/africa +31 (0) 40 2675 200 or fax +31 (0) 40 2675 222 in canada (800)-36-fluke or fax (905) 890-6866 from other countries +1 (425) 446-5500 or fax +1 (425) 446-5116 web access: http://www.fluke.com ?2012 fluke corporation. specifcations subject to change without notice. printed in u.s.a. 9/2012 4237028b_en modification of this document is not permitted without written permission from fluke corporation. fluke. the most trusted tools in the world. ordering information models description kits flk-cnx industrial kit fluke cnx 3000 industrial system includes multimeter, 3 iflex clamp modules, 1 voltage module and accessories flk-cnx 3000 general maintenance kit fluke cnx 3000 general maintenance system includes multimeter, iflex clamp module, voltage module and accessories flk-cnx 3000 hvac kit fluke cnx 3000 hvac kit system includes multimeter, ac current clamp module, temperature module and accessories flk-cnx t3000 kit fluke cnx t3000 kit includes multimeter, temperature module and accessories flk-cnx i3000 kit fluke cnx i3000 kit includes multimeter, iflex clamp module and accessories flk-cnx a3000 kit fluke cnx a3000 kit includes multimeter, ac current clamp module and accessories flk-cnx v3000 kit fluke cnx v3000 kit includes multimeter, voltage module and accessories modules flk-cnx 3000 series digi- tal multimeter flk-cnx 3000 digital multimeter and accessories flk-cnx 3000 series iflex ac current clamp module flk-cnx 3000 iflex module and iflex clamp flk-cnx 3000 series ac current clamp module flk-cnx 3000 ac current clamp module flk-cnx 3000 series ac voltage module flk-cnx 3000 ac voltage module and accessories flk-cnx 3000 series k-type temperature module flk-cnx 3000 k-type temperature module and accessory